<response><row><row _id="row-svz2-s4ta-ykm6" _uuid="00000000-0000-0000-6E5A-DBD1FA5108F9" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2369314"><pd_id>2369314</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>Dell EMC Unity XT380</brand_name><model_name>Dell EMC Unity XT380</model_name><model_number>Unity XT380</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC Unity XT380</storage_controller_model_name><storage_controller_model_number>Unity XT380</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>Unity Operating Environment</software_operating_environment_name><software_operating_environment_version>5.0.0.0.5.116</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>sample at 3 seconds report 30 second average, rolling</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC Unity XT 380</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Artesyn</trans_psu_manufacturer_name><trans_psu_model_name>"12V P/S WITH 12VSTBY AND FAN;700-013850-0100</trans_psu_model_name><trans_psu_model_number>"12V P/S WITH 12VSTBY AND FAN;700-013850-0100</trans_psu_model_number><trans_psu_rated_output_w>1100</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>12.88490189</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>22</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>6</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>16</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>54.40</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>17.55</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>2.74</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>53.78</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-27T00:00:00</date_available_on_market><date_qualified>2020-11-05T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_Unity XT380_11052020205009_5832924</energy_star_model_identifier></row><row _id="row-i532.za42.wtrz" _uuid="00000000-0000-0000-DAA4-96C2CB07BB27" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2369315"><pd_id>2369315</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>Dell EMC Unity XT380F</brand_name><model_name>Dell EMC Unity XT380F</model_name><model_number>Unity XT380F</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC Unity XT380F</storage_controller_model_name><storage_controller_model_number>Unity XT380F</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>Unity Operation Environment</software_operating_environment_name><software_operating_environment_version>5.0.3.0.5.014</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC Unity XT380F</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ARTESYN</trans_psu_manufacturer_name><trans_psu_model_name>12V P/S WITH 12VSTBY AND FAN</trans_psu_model_name><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>12.88490189</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>10</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>255.53</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>795.53</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>236.01</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>130.10</trans_optimal_point_ready_idle_workload_test_gb_w><trans_physical_or_modeled_data_device_1_optimal_point>Physical</trans_physical_or_modeled_data_device_1_optimal_point><trans_automated_tiering_enabled_during_testing_device_1>No</trans_automated_tiering_enabled_during_testing_device_1><date_available_on_market>2019-06-27T00:00:00</date_available_on_market><date_qualified>2020-11-05T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_Unity XT380F_11052020210241_2827802</energy_star_model_identifier></row><row _id="row-jumu_4fe5-5ep4" _uuid="00000000-0000-0000-BC76-3AC5C7257A94" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2369316"><pd_id>2369316</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>Dell EMC Unity XT480</brand_name><model_name>Dell EMC Unity XT480</model_name><model_number>Unity XT480</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC Unity XT480</storage_controller_model_name><storage_controller_model_number>Unity XT480</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>Unity Operating Environment</software_operating_environment_name><software_operating_environment_version>5.0.0.0.5.116</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC Unity XT480</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multioutput</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ACBEL POLYTECH INC.</trans_psu_manufacturer_name><trans_psu_model_name>12V P/S WITH 12VSTBY AND FAN;071-000-750-01</trans_psu_model_name><trans_psu_model_number>12V P/S WITH 12VSTBY AND FAN;071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1100</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>19.32735283</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>22</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>6</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>16</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>38.93</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>12.25</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>4.09</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>32.58</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-27T00:00:00</date_available_on_market><date_qualified>2020-11-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_Unity XT480_11062020101757_1221720</energy_star_model_identifier></row><row _id="row-tvhc-zg9i_6mvs" _uuid="00000000-0000-0000-C708-E4D698486B48" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2369317"><pd_id>2369317</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>Dell EMC Unity XT480F</brand_name><model_name>Dell EMC Unity XT480F</model_name><model_number>Unity XT480F</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC Unity XT480F</storage_controller_model_name><storage_controller_model_number>Unity XT480F</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>Unity Operating Environment</software_operating_environment_name><software_operating_environment_version>5.0.0.0.5.116</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC Unity XT480F</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ACBEL POLYTECH INC.</trans_psu_manufacturer_name><trans_psu_model_name>12V PS with 12V STBY and Fan; 071-000-750-01</trans_psu_model_name><trans_psu_model_number>12V PS with 12V STBY and Fan; 071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>19.32735283</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>10</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>10</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>238.76</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>843.04</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>234.18</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>72.96</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-27T00:00:00</date_available_on_market><date_qualified>2020-11-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_Unity XT480F_11062020103148_5866059</energy_star_model_identifier></row><row _id="row-iaci_h5zd.u993" _uuid="00000000-0000-0000-442A-00666A17656F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2381918"><pd_id>2381918</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>Dell EMC PowerStore 1000T</model_name><model_number>PowerStore 1000T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC PowerStore 1000T</storage_controller_model_name><storage_controller_model_number>PowerStore 1000T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>1.0.3.0.6.135</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>30</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>30</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC PowerStore 1000T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ACBEL POLYTECH INC</trans_psu_manufacturer_name><trans_psu_model_name>12V P/S WITH 12VSTBY AND FAN</trans_psu_model_name><trans_psu_model_number>071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>8.589934592</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>NVRAM</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>15</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>80.73</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>114.78</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>40.68</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>41.14</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2020-12-14T00:00:00</date_available_on_market><date_qualified>2021-07-12T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 1000T_07122021144015_9907455</energy_star_model_identifier></row><row _id="row-6dfc.akpd~mwjq" _uuid="00000000-0000-0000-9601-596E484662D3" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2382931"><pd_id>2382931</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>Dell EMC Unity XT680F</model_name><model_number>Unity XT680F</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC Unity XT680F</storage_controller_model_name><storage_controller_model_number>Unity XT680F</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>Unity Operating Environment</software_operating_environment_name><software_operating_environment_version>5.0.6.0.5.008</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC Unity XT680F</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ACBEL POLYTECH INC</trans_psu_manufacturer_name><trans_psu_model_name>12V P/S WITH 12VSTBY AND FAN</trans_psu_model_name><trans_psu_model_number>071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>19</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>19</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>321.23</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>942.56</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>259.91</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>24.54</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-27T00:00:00</date_available_on_market><date_qualified>2021-08-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_Unity XT680F_08062021143505_8680530</energy_star_model_identifier></row><row _id="row-gq32-tkef-f9uf" _uuid="00000000-0000-0000-9C64-66C76CB4AC7F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2389490"><pd_id>2389490</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>Dell EMC PowerStore 500T</model_name><model_number>PowerStore 500T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>Dell EMC PowerStore 500T</storage_controller_model_name><storage_controller_model_number>PowerStore 500T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>2.0.0.0-1371720</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>30</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>30</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>Dell EMC PowerStore 500T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>ACBEL POLYTECH INC</trans_psu_manufacturer_name><trans_psu_model_name>GEN2 CFF 1450W AC DC PSU AET</trans_psu_model_name><trans_psu_model_number>071-000-722-01</trans_psu_model_number><trans_psu_rated_output_w>1450</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>8.589934592</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>15</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>77.43</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>151.60</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>67.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>53.07</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-06-10T00:00:00</date_available_on_market><date_qualified>2021-12-08T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 500T_12082021151759_9896272</energy_star_model_identifier></row><row _id="row-mfjb.3axq-29rr" _uuid="00000000-0000-0000-8BC7-5ACE71694C2F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2668022"><pd_id>2668022</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerStore 1200T</model_name><model_number>PowerStore 1200T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>PowerStore 1200T</storage_controller_model_name><storage_controller_model_number>PowerStore 1200T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>3.5.0.0-2050321</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>PowerStore 1200T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_model_name>12V PS with 12V STBY and Fan</trans_psu_model_name><trans_psu_model_number>071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>130.14</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>183.62</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>71.76</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>36.42</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2022-07-21T00:00:00</date_available_on_market><date_qualified>2023-09-15T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 1200T_09152023144540_7612113</energy_star_model_identifier></row><row _id="row-mw3e.7y6e.dx8w" _uuid="00000000-0000-0000-69F0-24A3667737D0" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3387701"><pd_id>3387701</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerStore 3200T</model_name><model_number>PowerStore 3200T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>PowerStore 3200T</storage_controller_model_name><storage_controller_model_number>PowerStore 3200T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>3.5.0.0-2050321</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>PowerStore 3200T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_model_name>12V PS with 12V STBY and Fan</trans_psu_model_name><trans_psu_model_number>071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>134.03</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>467.95</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>131.75</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>32.41</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2022-07-21T00:00:00</date_available_on_market><date_qualified>2024-01-23T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 3200T_01232024102821_2660691</energy_star_model_identifier></row><row _id="row-4ifw~2hqc~qhk7" _uuid="00000000-0000-0000-311C-020B7302FBE4" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3477773"><pd_id>3477773</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerStore 5200T</model_name><model_number>PowerStore 5200T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>PowerStore 5200T</storage_controller_model_name><storage_controller_model_number>PowerStore 5200T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>3.5.0.0-2050321</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>PowerStore 5200T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_model_name>12V PS with 12V STBY and Fan</trans_psu_model_name><trans_psu_model_number>071-000-750-01</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>131.50</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>462.99</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>144.78</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>22.87</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2022-07-21T00:00:00</date_available_on_market><date_qualified>2024-05-09T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 5200T_05092024100649_4568196</energy_star_model_identifier></row><row _id="row-kztc.4y99.2fsr" _uuid="00000000-0000-0000-D72A-B043F6601CF3" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550151"><pd_id>3550151</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5012</model_number><additional_model_information>PowerVault,ME412</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M006 (12Gb SAS controller) E15M007 (32G Fibre Channel controller) E15M008 (25G SFP+ iSCSI controller) E15M009 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN210</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E09J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>3.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>7200.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>21474.83648</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>24</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>9.55</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>9.62</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>384.71</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5012_06282024130736_8231980</energy_star_model_identifier></row><row _id="row-ne2j-5tvz~5apw" _uuid="00000000-0000-0000-F7B0-22C781748172" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550156"><pd_id>3550156</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5024</model_number><additional_model_information>PowerVault,ME424</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M006 (12Gb SAS controller) E15M007 (32G Fibre Channel controller) E15M008 (25G SFP+ iSCSI controller) E15M009 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN210</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E10J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580- AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>2.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>10000.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>2576.980378</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>48</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>6.03</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>7.91</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>467.90</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5024_06282024142712_4414965</energy_star_model_identifier></row><row _id="row-4tfg_xbpr~uu6e" _uuid="00000000-0000-0000-C04E-40A1C578ED5C" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550160"><pd_id>3550160</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5084</model_number><additional_model_information>PowerVault,ME484</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M006 (12Gb SAS controller) E15M007 (32G Fibre Channel controller) E15M008 (25G SFP+ iSCSI controller) E15M009 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN210</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E11J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>UD-PCM2-2200- AC</stream_psu_model_number><stream_psu_rated_output_w>2200</stream_psu_rated_output_w><stream_psus_80plus_certification>Titanium</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>168</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>168</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>3.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>7200.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>19327.35283</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>168</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>2.37</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>2.30</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>1521.73</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5084_06282024135223_2694870</energy_star_model_identifier></row><row _id="row-xmzb.s96d_uf57" _uuid="00000000-0000-0000-02A2-060F8C71B34C" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3619611"><pd_id>3619611</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerStore 9200T</model_name><model_number>PowerStore 9200T</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Dell EMC Corporation</storage_controller_manufacturer_name><storage_controller_model_name>PowerStore 9200T</storage_controller_model_name><storage_controller_model_number>PowerStore 9200T</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>PowerStore Operating Environment</software_operating_environment_name><software_operating_environment_version>3.5.0.0-2050321</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3600</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3600</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Sample at 3 seconds, report 30 second average, rolling averages</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>PowerStore 9200T</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_model_name>12V PS with 12V STBY and Fan</trans_psu_model_name><trans_psu_model_number>071-000-760-03</trans_psu_model_number><trans_psu_rated_output_w>1450</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>15</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>266.85</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>874.51</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>306.98</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>43.89</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2022-07-21T00:00:00</date_available_on_market><date_qualified>2024-08-16T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_29573_PowerStore 9200T_08162024132027_4502711</energy_star_model_identifier></row><row _id="row-g96t~6sza.ni5i" _uuid="00000000-0000-0000-AC6D-50F1E17CB397" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4479469"><pd_id>4479469</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5284</model_number><additional_model_information>PowerVault,ME584</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M010 (12Gb SAS controller) E15M011 (32G Fibre Channel controller) E15M012 (25G SFP+ iSCSI controller) E15M013 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN310</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E11J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>UD-PCM2-2200AC</stream_psu_model_number><stream_psu_rated_output_w>2200</stream_psu_rated_output_w><stream_psus_80plus_certification>Titanium</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>168</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>168</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>3.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>7200.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>17999.99319</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>168</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>1.41</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>2.48</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>1521.38</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-22T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5284_07222025140239_7853539</energy_star_model_identifier></row><row _id="row-x5yp_cdpz~9cw8" _uuid="00000000-0000-0000-682F-630324CA38E4" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4479470"><pd_id>4479470</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5224</model_number><additional_model_information>PowerVault,ME524</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M010 (12Gb SAS controller) E15M011 (32G Fibre Channel controller) E15M012 (25G SFP+ iSCSI controller) E15M013 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN310</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E10J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>2.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>10000.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>2576.980378</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>48</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>7.04</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>7.65</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>481.86</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-22T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5224_07222025143616_8835780</energy_star_model_identifier></row><row _id="row-2yw6-xrvk-y8eb" _uuid="00000000-0000-0000-2922-B87CE77CEB04" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4479471"><pd_id>4479471</pd_id><energy_star_partner>Dell Inc.</energy_star_partner><brand_name>DELL</brand_name><model_name>PowerVault</model_name><model_number>ME5212</model_number><additional_model_information>PowerVault,ME512</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>E15M</storage_controller_model_name><storage_controller_model_number>E15M002 (Pimlico expander) E15M010 (12Gb SAS controller) E15M011 (32G Fibre Channel controller) E15M012 (25G SFP+ iSCSI controller) E15M013 (10BaseT controller)</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ME5</software_operating_environment_name><software_operating_environment_version>IN310</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>E09J</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>3.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>7200.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>21474.83648</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>24</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>7.72</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>8.81</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>437.06</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-07-01T00:00:00</date_available_on_market><date_qualified>2025-07-22T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_29573_ME5212_07222025150957_5921333</energy_star_model_identifier></row><row _id="row-brs8~3yj3_zjnw" _uuid="00000000-0000-0000-14A7-08F0DEE6AE6E" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2374875"><pd_id>2374875</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>Hewlett Packard Enterprise</brand_name><model_name>HPE MSA 2050 SFF Storage</model_name><model_number>HPE MSA 2050 SFF Storage</model_number><additional_model_information>HPE MSA 2052 SFF Storage,HPE MSA 2052 SFF Storage</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Cloud Systems, Inc.</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2050</storage_controller_model_name><storage_controller_model_number>LX2</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Raid</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>RealStor</software_operating_environment_name><software_operating_environment_version>VL100R004</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>user-selectable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>user-selectable</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2050 SFF Storage</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>Multi-Output</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Artesyn Embedded Technologies</stream_psu_manufacturer_name><stream_psu_model_name>81-00000104-00-01 REV A; HP SPS-PWR SUPPLY 595 W; 700-015147-0000; HPE SPS-PWR SUPPLY 627 W GOLD</stream_psu_model_name><stream_psu_model_number>81-00000104-00-01 REV A; HPE FRU 814665-001; 700-015147-0000; HPE FRU P22194-001</stream_psu_model_number><stream_psu_rated_output_w>627</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>18.44688454</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM,Other</stream_devices_used_for_cache><stream_other_devices_used_for_cache>4 GiB NVRAM</stream_other_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>4</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>2</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>No</stream_auto_tiering_enabled_optimal_point><stream_optimal_point_seq_read_workload_test_mibps_w>1.66</stream_optimal_point_seq_read_workload_test_mibps_w><stream_optimal_point_seq_write_workload_test_mibps_w>1.65</stream_optimal_point_seq_write_workload_test_mibps_w><stream_optimal_point_ready_idle_workload_test_gb_w>107.20</stream_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2017-06-02T00:00:00</date_available_on_market><date_qualified>2021-03-11T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_HPE MSA 2050 SFF Storage_03112021164103_3034669</energy_star_model_identifier></row><row _id="row-2gzq-6c4a_hnha" _uuid="00000000-0000-0000-CA58-5F05D8605178" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2374876"><pd_id>2374876</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>Hewlett Packard Enterprise</brand_name><model_name>HPE MSA 2050 LFF Storage</model_name><model_number>HPE MSA 2050 LFF Storage</model_number><additional_model_information>HPE MSA 2052 LFF Storage,HPE MSA 2052 LFF Storage</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Cloud Systems, Inc.</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2050</storage_controller_model_name><storage_controller_model_number>LX2</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Raid</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>RealStor</software_operating_environment_name><software_operating_environment_version>VL100R004</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>user-selectable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>user-selectable</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2050 LFF Storage</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>Multi-Output</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Artesyn Embedded Technologies</stream_psu_manufacturer_name><stream_psu_model_name>81-00000104-00-01 REV A; HPE FRU 814665-001; 700-015147-0000; HPE FRU P22194-001</stream_psu_model_name><stream_psu_model_number>81-00000104-00-01 REV A; HPE FRU 814665-001; 700-015147-0000; HPE FRU P22194-001</stream_psu_model_number><stream_psu_rated_output_w>627</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>18.44688454</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM,Other</stream_devices_used_for_cache><stream_other_devices_used_for_cache>4 GiB NVRAM</stream_other_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>4</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>2</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>No</stream_auto_tiering_enabled_optimal_point><stream_optimal_point_seq_read_workload_test_mibps_w>1.67</stream_optimal_point_seq_read_workload_test_mibps_w><stream_optimal_point_seq_write_workload_test_mibps_w>1.60</stream_optimal_point_seq_write_workload_test_mibps_w><stream_optimal_point_ready_idle_workload_test_gb_w>280.10</stream_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2017-06-02T00:00:00</date_available_on_market><date_qualified>2021-03-11T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_HPE MSA 2050 LFF Storage_03112021142253_7531585</energy_star_model_identifier></row><row _id="row-24k3_zfh2_6d7a" _uuid="00000000-0000-0000-25A2-B4C17E79F3B1" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2383325"><pd_id>2383325</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE Primera</brand_name><model_name>HPE Primera C630 2N</model_name><model_number>N9Z56A</model_number><snia_online_taxonomy_category>Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise</storage_controller_manufacturer_name><storage_controller_model_name>HPE Primera C630 2-node Controller</storage_controller_model_name><storage_controller_model_number>N9Z56A</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID 6</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Primera OS</software_operating_environment_name><software_operating_environment_version>4.0.0.146</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10s</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10s</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>HPE Primera C630 2N</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output (Controller Chassis); Multi-Output (JBOD)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Chicony (Controller Chassis); Chicony (JBOD)</trans_psu_manufacturer_name><trans_psu_model_name>HPE Primera 800W PCBM (Controller Chassis); HPE Primera 500W PCBM (JBOD)</trans_psu_model_name><trans_psu_model_number>S15-800P2A (Controller Chassis); S15-500P2A (JBOD)</trans_psu_model_number><trans_psu_rated_output_w>800W (Controller Chassis); 500W (JBOD)</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum (Controller Chassis); Platinum (JBOD)</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>281.3203579</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>72</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>0</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>72</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>6</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>3</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>15.54</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>83.82</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>5.64</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>161.76</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-19T00:00:00</date_available_on_market><date_qualified>2021-08-09T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_N9Z56A_08122021095216_7050215</energy_star_model_identifier></row><row _id="row-6pwd.zbw6~62nb" _uuid="00000000-0000-0000-6D78-95497EA01E76" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2383326"><pd_id>2383326</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE Primera</brand_name><model_name>HPE Primera C670 4N</model_name><model_number>N9Z67A/N9Z71A</model_number><snia_online_taxonomy_category>Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise</storage_controller_manufacturer_name><storage_controller_model_name>HPE Primera C670 1TB 4-node Controller</storage_controller_model_name><storage_controller_model_number>N9Z67A/N9Z71A</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID 6</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Primera OS</software_operating_environment_name><software_operating_environment_version>4.0.0.146</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10s</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10s</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>HPE Primera C670 4N</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output (Controller Chassis); Multi-Output (JBOD)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Chicony (Controller Chassis); Chicony (JBOD)</trans_psu_manufacturer_name><trans_psu_model_name>HPE Primera 1700W PCBM (Controller Chassis); HPE Primera 500W PCBM (JBOD)</trans_psu_model_name><trans_psu_model_number>S17-1K7P1A (Controller Chassis); S15-500P2A (JBOD)</trans_psu_model_number><trans_psu_rated_output_w>1700W (Controller Chassis); 500W (JBOD)</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum (Controller Chassis); Platinum (JBOD)</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>4294.967296</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>96</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>0</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>96</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>4</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>2</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>8</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>4</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>7.44</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>19.95</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>2.67</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>89.36</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-19T00:00:00</date_available_on_market><date_qualified>2021-08-09T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_N9Z67AN9Z71A_08122021095331_8995349</energy_star_model_identifier></row><row _id="row-rvh6_dfcb~zwbz" _uuid="00000000-0000-0000-08B0-F81E4E2B0147" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2383327"><pd_id>2383327</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE Primera</brand_name><model_name>HPE Primera C650 4N</model_name><model_number>N9Z63A</model_number><snia_online_taxonomy_category>Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise</storage_controller_manufacturer_name><storage_controller_model_name>HPE Primera C650 4-node Controller</storage_controller_model_name><storage_controller_model_number>N9Z63A</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID 6</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Primera OS</software_operating_environment_name><software_operating_environment_version>4.0.0.146</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10s</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10s</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>HPE Primera C650 4N</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output (Controller Chassis); Multi-Output (JBOD)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Chicony (Controller Chassis); Chicony (JBOD)</trans_psu_manufacturer_name><trans_psu_model_name>HPE Primera 1700W PCBM (Controller Chassis); HPE Primera 500W PCBM (JBOD)</trans_psu_model_name><trans_psu_model_number>S17-1K7P1A (Controller Chassis); S15-500P2A (JBOD)</trans_psu_model_number><trans_psu_rated_output_w>1700W (Controller Chassis); 500W (JBOD)</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum (Controller Chassis); Platinum (JBOD)</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>96</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>0</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>96</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>4</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>2</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>8</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>4</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>7.90</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>57.08</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>2.38</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>114.56</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-06-19T00:00:00</date_available_on_market><date_qualified>2021-08-09T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_N9Z63A_08122021095320_9584779</energy_star_model_identifier></row><row _id="row-ug8m-yc6q-a3pe" _uuid="00000000-0000-0000-201E-04F86640AE50" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2389942"><pd_id>2389942</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE Alletra 9080 2N/4N</model_name><model_number>R0N93A/R0N94A</model_number><snia_online_taxonomy_category>Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise Co.</storage_controller_manufacturer_name><storage_controller_model_name>HPE Alletra 9080</storage_controller_model_name><storage_controller_model_number>HPE Alletra 9080</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Scale-Up Storage</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Alletra Operating System</software_operating_environment_name><software_operating_environment_version>OS 9.4.0.59</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Typical Operating Temperature: 24.6C</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>R0N93A/R0N94A</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Chicony Power Technology Co., Ltd.</trans_psu_manufacturer_name><trans_psu_model_name>Switching Power Supply</trans_psu_model_name><trans_psu_model_number>S17-1K7P1B</trans_psu_model_number><trans_psu_rated_output_w>12Vdc, 141A</trans_psu_rated_output_w><trans_psus_80plus_certification>80+ Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>3298.534883</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>DIMMs</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>48</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>48</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>48</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>4</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>4</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>100.35</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>184.12</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>99.62</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>553.64</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-06-01T00:00:00</date_available_on_market><date_qualified>2021-12-28T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_R0N93A/R0N94A_122820211423567_9968216</energy_star_model_identifier></row><row _id="row-w7bs~p4jv.7urp" _uuid="00000000-0000-0000-9AF7-23232DB3C7C4" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2389987"><pd_id>2389987</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE Alletra 9060 2N/4N</model_name><model_number>R0N93A/R0N99A</model_number><snia_online_taxonomy_category>Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise Co.</storage_controller_manufacturer_name><storage_controller_model_name>HPE Alletra 9060</storage_controller_model_name><storage_controller_model_number>HPE Alletra 9060</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Scale-Up Storage</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Alletra Operating System</software_operating_environment_name><software_operating_environment_version>OS 9.4.0.59</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><power_and_temperature_reporting_additional_information>Typical Operating Temperature: 23.5C</power_and_temperature_reporting_additional_information><trans_model_number_or_config_id>R0N93A/R0N99A</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Chicony Power Technology Co., Ltd</trans_psu_manufacturer_name><trans_psu_model_name>Switching Power Supply</trans_psu_model_name><trans_psu_model_number>S17-1K7P1B</trans_psu_model_number><trans_psu_rated_output_w>12Vdc 141A</trans_psu_rated_output_w><trans_psus_80plus_certification>80+ Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>DIMMs</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>48</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>48</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>48</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>4</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>4</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>120.74</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>220.44</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>108.50</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>650.36</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-06-01T00:00:00</date_available_on_market><date_qualified>2021-12-28T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_R0N93A/R0N99A_122820211216255_9787932</energy_star_model_identifier></row><row _id="row-wtj5.rxna-vv3h" _uuid="00000000-0000-0000-9C4D-A3E23A527C57" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550166"><pd_id>3550166</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 2060 LFF Storage</model_name><model_number>HPE MSA 2060 LFF Storage</model_number><additional_model_information>HPE MSA 2062 LFF Storage,HPE MSA 2062 LFF Storage</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2060 SAN DC; HPE MSA 2060 SAN DC</storage_controller_model_name><storage_controller_model_number>HPE MSA 2060 SAN DC; HPE MSA 2060 SAN DC</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>20700</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>20700</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2060  LFF Storage; HPE  MSA 2062 LFF  Storage</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>26.39257403</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>3.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>7200.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>8.589934592</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>4</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>4.77</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>6.40</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>369.00</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2020-09-08T00:00:00</date_available_on_market><date_qualified>2024-06-27T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPE_MSA_2060_LFF_06302024111039_6055205</energy_star_model_identifier></row><row _id="row-msfj_wu3j_nw3d" _uuid="00000000-0000-0000-013A-0FBFAB59CA0D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550167"><pd_id>3550167</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 2060 SFF Storage</model_name><model_number>HPE MSA 2060 SFF Storage</model_number><additional_model_information>HPE MSA 2062 SFF Storage,HPE MSA 2062 SFF Storage</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2060  SAN DC; HPE  MSA 2060 SAN  DC</storage_controller_model_name><storage_controller_model_number>HPE MSA 2060  SAN DC; HPE  MSA 2060 SAN  DC</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>20700</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>20700</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2060  SAN DC,HPE  MSA 2060 SAN  DC</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>26.39257403</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>2.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>1500.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>1.932735283</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>4</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>5.21</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>7.63</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>104.16</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2020-12-22T00:00:00</date_available_on_market><date_qualified>2024-06-24T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPE_MSA_2060_SFF_06302024111039_6554305</energy_star_model_identifier></row><row _id="row-x7ih~byrx-nrr5" _uuid="00000000-0000-0000-A942-87471696F3A4" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3555238"><pd_id>3555238</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 1060 SFF Storage</model_name><model_number>HPE MSA 1060 SFF Storage</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 1060  FC; HPE MSA  1060 iSCSI; HPE  MSA 1060 SAS</storage_controller_model_name><storage_controller_model_number>HPE MSA 1060  FC; HPE MSA  1060 iSCSI; HPE  MSA 1060 SAS</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 1060  FC; HPE MSA  1060 iSCSI; HPE  MSA 1060 SAS</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>4</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>2</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>2.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>10000.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>2516.5824</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>48</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>10.75</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>9.76</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>347.20</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2022-08-10T00:00:00</date_available_on_market><date_qualified>2024-07-18T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPE_MSA_1060_SFF_07232024091736_3422824</energy_star_model_identifier></row><row _id="row-ssq4-nteh~jnmb" _uuid="00000000-0000-0000-CC6F-D5CE9C43078F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3814899"><pd_id>3814899</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE Alletra Storage MP B10140</model_name><model_number>HPE Alletra Storage MP B10140</model_number><additional_model_information>HPE Alletra Storage MP,B10000</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hewlett Packard Enterprise</storage_controller_manufacturer_name><storage_controller_model_name>HPE Alletra Storage MP</storage_controller_model_name><storage_controller_model_number>B10140</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Scale-Out Storage</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction,Streaming</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>HPE Alletra Storage ArcusOS</software_operating_environment_name><software_operating_environment_version>Version 10.4.2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>604800</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>N/A</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>B10140, B10000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Hewlett Packard Enterprise</trans_psu_manufacturer_name><trans_psu_model_name>P49921-001</trans_psu_model_name><trans_psu_model_number>P49921-001</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>RAM</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>14</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>14</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>387.48</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>2153.10</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>263.77</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>54.79</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2023-04-01T00:00:00</date_available_on_market><date_qualified>2024-11-26T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1128289_B10140_112620241633567_7426045</energy_star_model_identifier></row><row _id="row-a5nf-chga_wqdv" _uuid="00000000-0000-0000-CECB-C64C379CC07B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3943418"><pd_id>3943418</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 2070 SFF FC; HPE MSA 2070 SFF iSCSI; HPE MSA 2070 SFF SAS</model_name><model_number>HPE MSA 2070 SFF FC; HPE MSA 2070 SFF iSCSI; HPE MSA 2070 SFF SAS</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2070 SFF FC; HPE MSA 2070 SFF iSCSI; HPE MSA 2070 SFF SAS</storage_controller_model_name><storage_controller_model_number>HPE MSA 2070 SFF FC; HPE MSA 2070 SFF iSCSI; HPE MSA 2070 SFF SAS</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN300</software_operating_environment_name><software_operating_environment_version>IN300</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2070 SFF FC; HPE MSA 2070 SFF iSCSI; HPE MSA 2070 SFF SAS</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>580</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>2.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>10000.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>2399.995513</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>24</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>4.99</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>8.08</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>344.58</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2024-12-10T00:00:00</date_available_on_market><date_qualified>2025-01-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPEMSA2070SFF_01282025101848_5106846</energy_star_model_identifier></row><row _id="row-24mn-drf7_thfr" _uuid="00000000-0000-0000-5B5C-79437FE53E5F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3943419"><pd_id>3943419</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 2072 SFF FC; HPE MSA 2072 SFF iSCSI; HPE MSA 2072 SFF SAS</model_name><model_number>HPE MSA 2072 SFF FC; HPE MSA 2072 SFF iSCSI; HPE MSA 2072 SFF SAS</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2072 SFF FC; HPE MSA 2072 SFF iSCSI; HPE MSA 2072 SFF SAS</storage_controller_model_name><storage_controller_model_number>HPE MSA 2072 SFF FC; HPE MSA 2072 SFF iSCSI; HPE MSA 2072 SFF SAS</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN300</software_operating_environment_name><software_operating_environment_version>IN300</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2072 SFF FC; HPE MSA 2072 SFF iSCSI; HPE MSA 2072 SFF SAS</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>580</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>2</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>22</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>2.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>10000.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>2399.995513</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>24</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>4.90</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>8.08</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>342.10</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2024-12-10T00:00:00</date_available_on_market><date_qualified>2025-01-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPEMSA2072SFF_01282025103952_3429581</energy_star_model_identifier></row><row _id="row-ibrw~sjnd.mt2v" _uuid="00000000-0000-0000-077F-D68FF451C696" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3943420"><pd_id>3943420</pd_id><energy_star_partner>Hewlett Packard Enterprise</energy_star_partner><brand_name>HPE</brand_name><model_name>HPE MSA 2070 LFF FC; HPE MSA 2070 LFF iSCSI; HPE MSA 2070 LFF SAS</model_name><model_number>HPE MSA 2070 LFF FC; HPE MSA 2070 LFF iSCSI; HPE MSA 2070 LFF SAS</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>HPE MSA 2070 LFF FC; HPE MSA 2070 LFF iSCSI; HPE MSA 2070 LFF SAS</storage_controller_model_name><storage_controller_model_number>HPE MSA 2070 LFF FC; HPE MSA 2070 LFF iSCSI; HPE MSA 2070 LFF SAS</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN300</software_operating_environment_name><software_operating_environment_version>IN300</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HPE MSA 2070 LFF FC; HPE MSA 2070 LFF iSCSI; HPE MSA 2070 LFF SAS</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM4-PT580-AC</stream_psu_model_number><stream_psu_rated_output_w>580</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>12</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>12</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>3.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>7200.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>23999.38604</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>12</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>6.29</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>7.43</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>330.42</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2024-12-10T00:00:00</date_available_on_market><date_qualified>2025-01-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1128289_HPEMSA2070LFF_01282025110740_8764545</energy_star_model_identifier></row><row _id="row-qsvn~rer2_6uxw" _uuid="00000000-0000-0000-93D4-59F2C66F693F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2406086"><pd_id>2406086</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP E590</model_name><model_number>VSP E590, VSP E590H</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi, Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP E590</storage_controller_model_name><storage_controller_model_number>VSP E590</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS RF</software_operating_environment_name><software_operating_environment_version>9.8.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_total_amount_of_cache_gb>824.6337208</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>126.77</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>513.26</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>76.50</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>21.16</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-08-01T00:00:00</date_available_on_market><date_qualified>2022-12-20T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1109216_VSP E590, VSP E590H_121420221919330_2779017</energy_star_model_identifier></row><row _id="row-eek6~f7zm.qxcb" _uuid="00000000-0000-0000-8F77-694D1EA47855" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2406163"><pd_id>2406163</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP E1090</model_name><model_number>VSP E1090, VSP E1090H</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP E1090</storage_controller_model_name><storage_controller_model_number>VSP E1090</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS RF</software_operating_environment_name><software_operating_environment_version>9.8.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>368.86</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1447.83</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>113.59</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>16.55</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-12-01T00:00:00</date_available_on_market><date_qualified>2022-12-20T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1109216_VSP E1090, VSP E1090H_121420221917612_4347113</energy_star_model_identifier></row><row _id="row-9dik_bckq_zz9a" _uuid="00000000-0000-0000-EBAA-619BA63CAD9F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2406728"><pd_id>2406728</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP E790</model_name><model_number>VSP E790, VSP E790H</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi. Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP E790</storage_controller_model_name><storage_controller_model_number>VSP E790H</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS RF</software_operating_environment_name><software_operating_environment_version>9.8.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_total_amount_of_cache_gb>824.6337208</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>SSD</trans_devices_used_for_cache><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>274.17</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1309.92</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>97.24</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>16.79</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2020-12-01T00:00:00</date_available_on_market><date_qualified>2022-10-12T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1109216_VSP E790, VSP E790H_12142022192025_8645785</energy_star_model_identifier></row><row _id="row-wkfr_tq53.6b7x" _uuid="00000000-0000-0000-F448-B24CEDFE4FE0" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3624365"><pd_id>3624365</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP One B26</model_name><model_number>VSP One B26</model_number><upc>496131199422</upc><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi, Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP One B26</storage_controller_model_name><storage_controller_model_number>VSP One B26</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS</software_operating_environment_name><software_operating_environment_version>10.2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics (Thailand) Public Co., Ltd.</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-1800FB A</trans_psu_model_name><trans_psu_model_number>TDPS-1800FB A</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>549.7558139</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>8</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>408.61</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>963.14</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>190.74</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>18.16</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-07-01T00:00:00</date_available_on_market><date_qualified>2024-08-13T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1109216_VSP One B26_08142024122400_2442746</energy_star_model_identifier></row><row _id="row-axyr~6cqh-2uk8" _uuid="00000000-0000-0000-F3DD-9EF4D25F3235" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3624366"><pd_id>3624366</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP One B28</model_name><model_number>VSP One B28</model_number><upc>496131199422</upc><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi, Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP One B28</storage_controller_model_name><storage_controller_model_number>VSP One B28</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS</software_operating_environment_name><software_operating_environment_version>10.2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics (Thailand) Public Co., Ltd.</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-1800FB A</trans_psu_model_name><trans_psu_model_number>TDPS-1800FB A</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>8</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>537.80</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>781.87</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>222.33</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>15.12</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-07-01T00:00:00</date_available_on_market><date_qualified>2024-08-13T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1109216_VSP One B28_08262024114007_8707012</energy_star_model_identifier></row><row _id="row-md39.rnze~ar59" _uuid="00000000-0000-0000-0EB2-25E78A142822" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3629827"><pd_id>3629827</pd_id><energy_star_partner>Hitachi Vantara LLC</energy_star_partner><brand_name>Hitachi Vantara</brand_name><model_name>VSP One B24</model_name><model_number>VSP One B24</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Hitachi, Ltd.</storage_controller_manufacturer_name><storage_controller_model_name>VSP One B24</storage_controller_model_name><storage_controller_model_number>VSP One B24</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SVOS</software_operating_environment_name><software_operating_environment_version>10.2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>60</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>60</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics (Thailand) Public Co., Ltd.</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-1800FB A</trans_psu_model_name><trans_psu_model_number>TDPS-1800FB A</trans_psu_model_number><trans_psu_rated_output_w>1800</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>274.8779069</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>8</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>216.70</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>891.21</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>132.66</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>20.21</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-07-01T00:00:00</date_available_on_market><date_qualified>2024-10-01T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1109216_VSP One B24_10012024143023_5296582</energy_star_model_identifier></row><row _id="row-aseh.52zw.xs7b" _uuid="00000000-0000-0000-A66A-0C159DD62AE1" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4680454"><pd_id>4680454</pd_id><energy_star_partner>Huawei Technologies Co., Ltd.</energy_star_partner><brand_name>HUAWEI</brand_name><model_name>OceanStor Dorado 3000</model_name><model_number>OceanStor Dorado 3000</model_number><additional_model_information>OceanStor 5310; OceanStor 5310 Capacity Flash Storage; SPE36C0212; SPE36C0225; SPE62C0225</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>HUAWEI</storage_controller_manufacturer_name><storage_controller_model_name>OceanStor Dorado 3000</storage_controller_model_name><storage_controller_model_number>OceanStor Dorado 3000</storage_controller_model_number><storage_controller_advanced_data_recovery_type>EC</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>EulerOS</software_operating_environment_name><software_operating_environment_version>2.0 (SP13)</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>OceanStor Dorado 3000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output
(Ac-Dc)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>HUAWEI</trans_psu_manufacturer_name><trans_psu_model_name>PAC2000S12-BG</trans_psu_model_name><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>137.4389535</trans_total_amount_of_cache_gb><trans_optimal_point_hot_band_workload_test_iops_w>561.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1818.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>357.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>36.62</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-09-30T00:00:00</date_available_on_market><date_qualified>2026-07-22T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1100906_OceanStor Dorado 3000_07032026090828_188562</energy_star_model_identifier></row><row _id="row-nn2t-3q2y~78jb" _uuid="00000000-0000-0000-6A13-1C45B8FA825A" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4682814"><pd_id>4682814</pd_id><energy_star_partner>Huawei Technologies Co., Ltd.</energy_star_partner><brand_name>HUAWEI</brand_name><model_name>OceanStor Dorado 5000</model_name><model_number>OceanStor Dorado 5000</model_number><additional_model_information>OceanStor 5510; OceanStor 5510 Capacity Flash Storage; OceanStor 5610; SPE53C0212; SPE53C0225; SPE63C0236</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>HUAWEI</storage_controller_manufacturer_name><storage_controller_model_name>OceanStor Dorado 5000</storage_controller_model_name><storage_controller_model_number>OceanStor Dorado 5000</storage_controller_model_number><storage_controller_advanced_data_recovery_type>EC</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>EulerOS</software_operating_environment_name><software_operating_environment_version>2.0 (SP13)</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>OceanStor Dorado 5000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output
(Ac-Dc)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>HUAWEI</trans_psu_manufacturer_name><trans_psu_model_name>PAC2000S12-B1</trans_psu_model_name><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>549.7558139</trans_total_amount_of_cache_gb><trans_optimal_point_hot_band_workload_test_iops_w>495.62</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>319.64</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>1214.11</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>41.05</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-09-30T00:00:00</date_available_on_market><date_qualified>2026-08-05T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1100906_OceanStor Dorado 5000_07302026183131_6419641</energy_star_model_identifier></row><row _id="row-qeq8-7atr~mbbn" _uuid="00000000-0000-0000-5147-69761F4FEEBD" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4687974"><pd_id>4687974</pd_id><energy_star_partner>Huawei Technologies Co., Ltd.</energy_star_partner><brand_name>HUAWEI</brand_name><model_name>OceanStor Dorado 6000</model_name><model_number>OceanStor Dorado 6000</model_number><additional_model_information>SPE52C0225; SPE62C0236; SPE64C0236</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>HUAWEI</storage_controller_manufacturer_name><storage_controller_model_name>OceanStor Dorado 6000</storage_controller_model_name><storage_controller_model_number>OceanStor Dorado 6000</storage_controller_model_number><storage_controller_advanced_data_recovery_type>EC</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>EulerOS</software_operating_environment_name><software_operating_environment_version>2.0 (SP13)</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>OceanStor Dorado 6000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output
(Ac-Dc)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>HUAWEI</trans_psu_manufacturer_name><trans_psu_model_name>PAC3K2S12-T1</trans_psu_model_name><trans_psu_rated_output_w>3000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>2199.023256</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_optimal_point_hot_band_workload_test_iops_w>848.81</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1246.89</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>506.57</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>93.28</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-09-30T00:00:00</date_available_on_market><date_qualified>2026-08-11T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1100906_OceanStor Dorado 6000_08052026160439_7421533</energy_star_model_identifier></row><row _id="row-9r86_atrk.xrsa" _uuid="00000000-0000-0000-1E2D-46EE9BF3E43C" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4693254"><pd_id>4693254</pd_id><energy_star_partner>Huawei Technologies Co., Ltd.</energy_star_partner><brand_name>HUAWEI</brand_name><model_name>OceanStor Dorado 18000</model_name><model_number>OceanStor Dorado 18000</model_number><additional_model_information>DAE62435U4; DAE62525U2-10; DAE72525U2-20; DAE73625U2; OceanStor 18810; SPE74C0400</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>HUAWEI</storage_controller_manufacturer_name><storage_controller_model_name>OceanStor Dorado 18000</storage_controller_model_name><storage_controller_model_number>OceanStor Dorado 18000</storage_controller_model_number><storage_controller_advanced_data_recovery_type>EC</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>EulerOS</software_operating_environment_name><software_operating_environment_version>2.0 (SP13)</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>OceanStor Dorado 18000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output
(Ac-Dc)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>HUAWEI</trans_psu_manufacturer_name><trans_psu_model_name>PAC3K2S12-T1</trans_psu_model_name><trans_psu_rated_output_w>3000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>2199.023256</trans_total_amount_of_cache_gb><trans_optimal_point_hot_band_workload_test_iops_w>346.06</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1124.47</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>265.93</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>41.05</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-09-30T00:00:00</date_available_on_market><date_qualified>2026-08-24T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1100906_OceanStor Dorado 18000_08212026132159_3352624</energy_star_model_identifier></row><row _id="row-8549.7n4c-8y7p" _uuid="00000000-0000-0000-0425-EDBF43AAA65D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4694934"><pd_id>4694934</pd_id><energy_star_partner>Huawei Technologies Co., Ltd.</energy_star_partner><brand_name>HUAWEI</brand_name><model_name>OceanStor Dorado 8000</model_name><model_number>OceanStor Dorado 8000</model_number><additional_model_information>OceanStor 18510; OceanStor 6810; SPE75C0400</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>HUAWEI</storage_controller_manufacturer_name><storage_controller_model_name>OceanStor Dorado 8000</storage_controller_model_name><storage_controller_model_number>OceanStor Dorado 8000</storage_controller_model_number><storage_controller_advanced_data_recovery_type>EC</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>EulerOS</software_operating_environment_name><software_operating_environment_version>2.0 (SP13)</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>3</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>3</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>OceanStor Dorado 8000</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output
(Ac-Dc)</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>HUAWEI</trans_psu_manufacturer_name><trans_psu_model_name>PAC3K2S12-T1</trans_psu_model_name><trans_psu_rated_output_w>3000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>4398.046511</trans_total_amount_of_cache_gb><trans_optimal_point_hot_band_workload_test_iops_w>527.15</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1038.44</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>387.63</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>59.24</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-09-30T00:00:00</date_available_on_market><date_qualified>2026-08-31T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1100906_OceanStor Dorado 8000_08272026100745_9192773</energy_star_model_identifier></row><row _id="row-w4tk.a9kf-unpv" _uuid="00000000-0000-0000-EB3C-FF1E5025CA29" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2381270"><pd_id>2381270</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 7200</model_name><model_number>2076-824</model_number><additional_model_information>FS7200,2076-U7C</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 7200</storage_controller_model_name><storage_controller_model_number>2076-824; 2076-U7C</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL4 SP2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>5</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Compuware Technology Inc.</trans_psu_manufacturer_name><trans_psu_model_name>CPR-2021-2M1</trans_psu_model_name><trans_psu_model_number>02YC415</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>2000</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>274.8779069</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>12</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>12</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>2</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>256.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>987.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>210.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>26.50</trans_optimal_point_ready_idle_workload_test_gb_w><trans_storage_device_1_type>Solid State Drive (SSD)</trans_storage_device_1_type><trans_storage_device_1_form_factor>2.5 inch</trans_storage_device_1_form_factor><trans_storage_device_1_rated_speed_rpm>0.00</trans_storage_device_1_rated_speed_rpm><trans_storage_device_1_raw_capacity_gb>2061.584302</trans_storage_device_1_raw_capacity_gb><trans_num_devices_storage_device_1_optimal_point>12</trans_num_devices_storage_device_1_optimal_point><trans_physical_or_modeled_data_device_1_optimal_point>Physical</trans_physical_or_modeled_data_device_1_optimal_point><trans_automated_tiering_enabled_during_testing_device_1>No</trans_automated_tiering_enabled_during_testing_device_1><trans_device_1_optimal_point_hot_band_wrkld_test_iops_w>256.00</trans_device_1_optimal_point_hot_band_wrkld_test_iops_w><trans_device_1_optimal_point_random_read_wrkld_test_iops_w>987.00</trans_device_1_optimal_point_random_read_wrkld_test_iops_w><trans_device_1_optimal_point_random_write_wrkld_test_iops_w>210.00</trans_device_1_optimal_point_random_write_wrkld_test_iops_w><trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w>26.50</trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2020-02-11T00:00:00</date_available_on_market><date_qualified>2021-04-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_2076-824_06252021003424_1303954</energy_star_model_identifier></row><row _id="row-m8wk.hdrj_tszw" _uuid="00000000-0000-0000-D996-1E698639E12B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2381271"><pd_id>2381271</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 5200</model_name><model_number>4662-6H2</model_number><additional_model_information>FS5200,4662-UH6</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 5200</storage_controller_model_name><storage_controller_model_number>4662-6H2; 4662-UH6</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Compression</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL4 SP2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>5</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4662-6H2</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>IBM</trans_psu_manufacturer_name><trans_psu_model_name>Delta Electronics</trans_psu_model_name><trans_psu_model_number>AWF-2DC-1500W</trans_psu_model_number><trans_psu_rated_output_w>1500</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>274.8779069</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>8</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>281.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>950.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>121.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>438.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-02-09T00:00:00</date_available_on_market><date_qualified>2021-04-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_2072-6H2_06252021003436_6844789</energy_star_model_identifier></row><row _id="row-rysr_bp2w-mr4w" _uuid="00000000-0000-0000-5D95-3FE270217AC7" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2393050"><pd_id>2393050</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 5045</model_name><model_number>4680-3P2</model_number><additional_model_information>FS5045,4680-3P4</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 5045</storage_controller_model_name><storage_controller_model_number>4680-3P4</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL4 SP4</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>5</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4680-3P4</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>IBM</trans_psu_manufacturer_name><trans_psu_model_name>Delta Electronics</trans_psu_model_name><trans_psu_model_number>TDPS-800FB A</trans_psu_model_number><trans_psu_rated_output_w>800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>68.71947674</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>6</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>6</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>427.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1400.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>252.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>100.48</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-02-09T00:00:00</date_available_on_market><date_qualified>2022-01-15T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_2072-3N4_02162022111755_3653165</energy_star_model_identifier></row><row _id="row-p4ww_5acd.92px" _uuid="00000000-0000-0000-2D1F-9F2E5DBB9B80" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2393051"><pd_id>2393051</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 5015</model_name><model_number>4680-2P2</model_number><additional_model_information>FS5015,4680-2P4</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 5015</storage_controller_model_name><storage_controller_model_number>4680-2P4</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL4 SP4</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>5</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4680-2P4</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>IBM</trans_psu_manufacturer_name><trans_psu_model_name>AcBel</trans_psu_model_name><trans_psu_model_number>SGE006-030G</trans_psu_model_number><trans_psu_rated_output_w>800</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>68.71947674</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>6</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>6</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>212.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>594.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>128.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>117.50</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-02-09T00:00:00</date_available_on_market><date_qualified>2022-02-15T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_2072-2N4_02162022112410_2425521</energy_star_model_identifier></row><row _id="row-fdfr~x4qy.6rss" _uuid="00000000-0000-0000-62BC-7FDC459D9164" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2732776"><pd_id>2732776</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 7300</model_name><model_number>4657-924</model_number><additional_model_information>FS7300,4657-U7D</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 7300</storage_controller_model_name><storage_controller_model_number>4657-924; 4657-U7D</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL5 SR6</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>30</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>30</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4657-924</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-2000AB-18 A</trans_psu_model_name><trans_psu_model_number>TDPS-2000AB-18 A</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>414.4643441</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>12</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>100</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>12</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>330.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1090.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>242.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>39.40</trans_optimal_point_ready_idle_workload_test_gb_w><trans_storage_device_1_type>Solid State Drive (SSD)</trans_storage_device_1_type><trans_storage_device_1_form_factor>2.5 inch</trans_storage_device_1_form_factor><trans_storage_device_1_rated_speed_rpm>0.00</trans_storage_device_1_rated_speed_rpm><trans_storage_device_1_raw_capacity_gb>3848.290697</trans_storage_device_1_raw_capacity_gb><trans_num_devices_storage_device_1_optimal_point>12</trans_num_devices_storage_device_1_optimal_point><trans_physical_or_modeled_data_device_1_optimal_point>Physical</trans_physical_or_modeled_data_device_1_optimal_point><trans_automated_tiering_enabled_during_testing_device_1>Yes</trans_automated_tiering_enabled_during_testing_device_1><trans_device_1_optimal_point_hot_band_wrkld_test_iops_w>330.00</trans_device_1_optimal_point_hot_band_wrkld_test_iops_w><trans_device_1_optimal_point_random_read_wrkld_test_iops_w>1090.00</trans_device_1_optimal_point_random_read_wrkld_test_iops_w><trans_device_1_optimal_point_random_write_wrkld_test_iops_w>242.00</trans_device_1_optimal_point_random_write_wrkld_test_iops_w><trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w>39.40</trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2022-03-04T00:00:00</date_available_on_market><date_qualified>2023-10-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_4657-924_11082023101414_8464037</energy_star_model_identifier></row><row _id="row-zvq2.infc~5axh" _uuid="00000000-0000-0000-F4E3-FFEE2D6C169D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2732777"><pd_id>2732777</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 9500</model_name><model_number>4666-AH8</model_number><additional_model_information>4983-AH8; FS9500,4666-UH8</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 9500</storage_controller_model_name><storage_controller_model_number>4666-AH8; 4666-UH8; 4983-AH8</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL5 SR6</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>30</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>30</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4666-AH8</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-2000JB A</trans_psu_model_name><trans_psu_model_number>TDPS-2000JB A</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1099.511628</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>100</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>156.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>589.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>230.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>22.00</trans_optimal_point_ready_idle_workload_test_gb_w><trans_storage_device_1_type>Solid State Drive (SSD)</trans_storage_device_1_type><trans_storage_device_1_form_factor>2.5 inch</trans_storage_device_1_form_factor><trans_storage_device_1_rated_speed_rpm>0.00</trans_storage_device_1_rated_speed_rpm><trans_storage_device_1_raw_capacity_gb>1924.145349</trans_storage_device_1_raw_capacity_gb><trans_num_devices_storage_device_1_optimal_point>24</trans_num_devices_storage_device_1_optimal_point><trans_physical_or_modeled_data_device_1_optimal_point>Physical</trans_physical_or_modeled_data_device_1_optimal_point><trans_automated_tiering_enabled_during_testing_device_1>Yes</trans_automated_tiering_enabled_during_testing_device_1><trans_device_1_optimal_point_hot_band_wrkld_test_iops_w>156.00</trans_device_1_optimal_point_hot_band_wrkld_test_iops_w><trans_device_1_optimal_point_random_read_wrkld_test_iops_w>589.00</trans_device_1_optimal_point_random_read_wrkld_test_iops_w><trans_device_1_optimal_point_random_write_wrkld_test_iops_w>230.00</trans_device_1_optimal_point_random_write_wrkld_test_iops_w><trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w>22.00</trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2022-02-08T00:00:00</date_available_on_market><date_qualified>2023-10-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_4666-AH8_11152023154943_9375118</energy_star_model_identifier></row><row _id="row-5iwj-ghqs~v4zk" _uuid="00000000-0000-0000-551D-FBEE2BDFAB30" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3624364"><pd_id>3624364</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 9500</model_name><model_number>4666-AH8</model_number><additional_model_information>4983-AH8; FS9500,4666-UH8</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 9500</storage_controller_model_name><storage_controller_model_number>4666-AH8; 4666-UH8; 4983-AH8</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID5; DRAID6; RAID10</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.2 TL5 SR6</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>Active Cooling</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>30</length_of_rolling_average_for_inlet_air_temperature_s><date_available_on_market>2022-02-08T00:00:00</date_available_on_market><date_qualified>2023-10-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_4666-AH8_08202024223619_6508786</energy_star_model_identifier></row><row _id="row-rbfx~ya3y~vb9k" _uuid="00000000-0000-0000-2D84-FE088ABFBD93" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4005739"><pd_id>4005739</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem 5300</model_name><model_number>4662-7H2</model_number><additional_model_information>FS5300</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem 5300</storage_controller_model_name><storage_controller_model_number>4662-7H2</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID6</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.3 TL2 SR3</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>user-selectable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>user-selectable</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>4662-7H2</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-1500AB-11A</trans_psu_model_name><trans_psu_model_number>TDPS-1500AB-11A</trans_psu_model_number><trans_psu_rated_output_w>1500</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>549.7558139</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>8</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>395.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>1026.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>368.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>398.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-04-23T00:00:00</date_available_on_market><date_qualified>2025-03-12T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_4662-7H2_03252025135054_3782391</energy_star_model_identifier></row><row _id="row-42kt.58qz.ybpj" _uuid="00000000-0000-0000-412B-8809AE22DCB8" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4596174"><pd_id>4596174</pd_id><energy_star_partner>IBM Corporation</energy_star_partner><brand_name>IBM</brand_name><model_name>IBM FlashSystem C200</model_name><model_number>5202-C25</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>IBM</storage_controller_manufacturer_name><storage_controller_model_name>IBM FlashSystem C200</storage_controller_model_name><storage_controller_model_number>5202-C25</storage_controller_model_number><storage_controller_advanced_data_recovery_type>DRAID6</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Data Deduplication,Delta Snapshots,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>AIX</software_operating_environment_name><software_operating_environment_version>7.3 TL2 SR3</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>user-selectable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>user-selectable</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>5202-C25</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-2000AB-18A</trans_psu_model_name><trans_psu_model_number>TDPS-2000AB-18A</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>274.8779069</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>12</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>12</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>162.60</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>498.40</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>98.50</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>695.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-03-21T00:00:00</date_available_on_market><date_qualified>2026-04-23T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_40266_5202-C25_05042026130114_9579327</energy_star_model_identifier></row><row _id="row-wtkx.r5pw_9dnr" _uuid="00000000-0000-0000-41A9-2F8D09FBBB96" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2378360"><pd_id>2378360</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo</brand_name><model_name>ThinkSystem</model_name><model_number>DS6200 - 4619 DS LFF EXP - 4588</model_number><additional_model_information>ThinkSystem,DS6200 - 4619 DS LFF EXP - 4588,5535 and J1212 are Machine Type Numbers for Lenovo Group Limited</additional_model_information><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Cloud
Systems, Inc.</storage_controller_manufacturer_name><storage_controller_model_name>RealStor 5005</storage_controller_model_name><storage_controller_model_number>GaNX3</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>RealStor</software_operating_environment_name><software_operating_environment_version>2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>20700</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>20700</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>RealStor 5005</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-
HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584W</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_other_devices_used_for_cache>Yes</stream_other_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>36</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>36</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>11.68</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>9.42</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>77.20</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2017-06-29T00:00:00</date_available_on_market><date_qualified>2017-08-01T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_DS6200 - 4619 DS LFF EXP - 4588_07302017210437_6202204</energy_star_model_identifier></row><row _id="row-zbjq-icbz~zmwf" _uuid="00000000-0000-0000-E5F6-0154A8501347" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2402399"><pd_id>2402399</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo (United States) Inc.</brand_name><model_name>DE6400F/DE6400H</model_name><model_number>7DB6</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>DE6400F/DE6400H</storage_controller_model_name><storage_controller_model_number>7DB6</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>11.70R3</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>DPS-160AB-18 C</trans_psu_model_name><trans_psu_model_number>DPS-160AB-18 C</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>1073.741824</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>232.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>809.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>123.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>422.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2020-10-15T00:00:00</date_available_on_market><date_qualified>2021-06-15T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_7DB6_20229104160033_9316299</energy_star_model_identifier></row><row _id="row-9tk8_8wqq~xr93" _uuid="00000000-0000-0000-B566-4065B09A103B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2402400"><pd_id>2402400</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo (United States) Inc.</brand_name><model_name>DE6600F/DE6600H</model_name><model_number>7DB7</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Lenovo (United States) Inc.</storage_controller_manufacturer_name><storage_controller_model_name>DE6600F/DE6600H</storage_controller_model_name><storage_controller_model_number>7DB7</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>88.60.45.71.000</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>DPS-160AB-18 B</trans_psu_model_name><trans_psu_model_number>DPS-160AB-18 B</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>3840.774504</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>242.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>452.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>283.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>158.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2022-09-21T00:00:00</date_available_on_market><date_qualified>2022-10-04T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_7DB7_20229104145632_2427150</energy_star_model_identifier></row><row _id="row-txrf-78sb~hyhy" _uuid="00000000-0000-0000-7D2E-8FEB9872528B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3629790"><pd_id>3629790</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo (United States) Inc.</brand_name><model_name>DE4000H</model_name><model_number>7Y74</model_number><additional_model_information>DE2000H,7Y70</additional_model_information><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>DE4000H</storage_controller_model_name><storage_controller_model_number>7Y74</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900AB A</trans_psu_model_name><trans_psu_model_number>TDPS-900AB A</trans_psu_model_number><trans_psu_rated_output_w>913</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>8589.934592</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>12</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>12</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>7.20</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>2.50</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>5.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>276.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-09-16T00:00:00</date_available_on_market><date_qualified>2018-01-22T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_7Y70,7Y74_20248129153714_7477588</energy_star_model_identifier></row><row _id="row-7rek~z53t.sgjq" _uuid="00000000-0000-0000-3A56-51D40A20D9DE" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3629791"><pd_id>3629791</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo (United States) Inc.</brand_name><model_name>DE2000H</model_name><model_number>7Y71</model_number><additional_model_information>DE4000H,7Y75</additional_model_information><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>DE2000H</storage_controller_model_name><storage_controller_model_number>7Y71</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900AB A</trans_psu_model_name><trans_psu_model_number>TDPS-900AB A</trans_psu_model_number><trans_psu_rated_output_w>913</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>1932.735283</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>24</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>28.10</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>9.50</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>13.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>104.10</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-09-16T00:00:00</date_available_on_market><date_qualified>2024-09-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_7Y71_20248130143906_3546762</energy_star_model_identifier></row><row _id="row-tk23.iyxi_7m4h" _uuid="00000000-0000-0000-EE70-17C621B8087D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3629792"><pd_id>3629792</pd_id><energy_star_partner>Lenovo Group Limited</energy_star_partner><brand_name>Lenovo (United States) Inc.</brand_name><model_name>DE4000H</model_name><model_number>7Y77</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>DE4000H</storage_controller_model_name><storage_controller_model_number>7Y77</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>Delta TDPS-2325AB</trans_psu_model_name><trans_psu_model_number>TDPS-2325AB</trans_psu_model_number><trans_psu_rated_output_w>2325</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>8589.934592</trans_total_amount_of_cache_gb><trans_other_devices_used_for_cache>HDD</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>60</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>60</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>16.60</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>3.40</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>5.80</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>420.40</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2024-09-16T00:00:00</date_available_on_market><date_qualified>2024-09-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1037540_7Y77_20248130150155_3790860</energy_star_model_identifier></row><row _id="row-bi9s-m2eu_p9pp" _uuid="00000000-0000-0000-321B-E2DE4C58BF92" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2376090"><pd_id>2376090</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>EF-Series</model_name><model_number>EF600</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>EF-Series</storage_controller_model_name><storage_controller_model_number>EF600</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>88.60.45.71.000</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>DPS-1600AB-18 B</trans_psu_model_name><trans_psu_model_number>DPS-1600AB-18 B</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>3840.774504</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>242.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>452.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>283.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>158.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2019-09-30T00:00:00</date_available_on_market><date_qualified>2019-08-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_EF600_20198103135614_4243543</energy_star_model_identifier></row><row _id="row-aw6r~96cd.kjra" _uuid="00000000-0000-0000-5284-36094A27236A" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2376105"><pd_id>2376105</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp, Inc.</brand_name><model_name>E2800 Series (E-Series)</model_name><model_number>E2812</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>NetApp E2800</storage_controller_model_name><storage_controller_model_number>E2800</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>NetApp E-Series SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900AB A</trans_psu_model_name><trans_psu_model_number>TDPS-900AB A</trans_psu_model_number><trans_psu_rated_output_w>913</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>8589.934592</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>HDD</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>12</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>12</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>7.20</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>2.50</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>5.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>276.40</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2016-07-01T00:00:00</date_available_on_market><date_qualified>2018-01-22T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_E2812_20180124083723_5985458</energy_star_model_identifier></row><row _id="row-22bi-ed2w-9kbr" _uuid="00000000-0000-0000-DBDD-1184FAB9CDEC" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2376106"><pd_id>2376106</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp, Inc.</brand_name><model_name>E2800 Series (E-Series)</model_name><model_number>E2860</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>NetApp E2800</storage_controller_model_name><storage_controller_model_number>E2800</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>NetApp E-Series SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>Delta TDPS-2325AB</trans_psu_model_name><trans_psu_model_number>TDPS-2325AB</trans_psu_model_number><trans_psu_rated_output_w>2325</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>8589.934592</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>HDD</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>60</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>60</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>16.60</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>3.40</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>5.80</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>420.40</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2016-07-01T00:00:00</date_available_on_market><date_qualified>2018-01-22T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_E2860_20180124085741_2963494</energy_star_model_identifier></row><row _id="row-v9j9.87qt_kk8s" _uuid="00000000-0000-0000-41A0-3B53F35C3691" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2376144"><pd_id>2376144</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp, Inc.</brand_name><model_name>E2800 Series (E-Series)</model_name><model_number>E2824</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>NetApp E2800</storage_controller_model_name><storage_controller_model_number>E2800</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>NetApp E-Series SANtricity</software_operating_environment_name><software_operating_environment_version>08.40.00.00</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900AB A</trans_psu_model_name><trans_psu_model_number>TDPS-900AB A</trans_psu_model_number><trans_psu_rated_output_w>913</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>1932.735283</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>0</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>24</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>28.10</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>9.50</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>13.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>104.10</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2016-07-01T00:00:00</date_available_on_market><date_qualified>2018-01-22T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_E2824_20180122121302_3307361</energy_star_model_identifier></row><row _id="row-swa3~374y_irsh" _uuid="00000000-0000-0000-D724-F348AE6DEEC7" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2380282"><pd_id>2380282</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>EF-Series</model_name><model_number>EF300</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>EF-Series</storage_controller_model_name><storage_controller_model_number>EF300</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANtricity</software_operating_environment_name><software_operating_environment_version>11.70R3</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>DPS-160AB-18 C</trans_psu_model_name><trans_psu_model_number>DPS-160AB-18 C</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>1073.741824</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_ratio_devices_mixed_optimal_point>1</trans_ratio_devices_mixed_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_installed_rotational_devices_in_optimal_point>0</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>2</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>1</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>1</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>232.00</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>809.00</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>123.00</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>422.00</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2020-10-15T00:00:00</date_available_on_market><date_qualified>2021-06-15T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_EF300_20215121151416_9457671</energy_star_model_identifier></row><row _id="row-mbwr.ntxz~24t7" _uuid="00000000-0000-0000-E485-772F2D26E9CB" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2386935"><pd_id>2386935</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A-Series</model_name><model_number>AFF A250</model_number><additional_model_information>AFF A-Series,AFF C250</additional_model_information><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>AFF A-Series</storage_controller_model_name><storage_controller_model_number>AFF A250</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.9.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics</trans_psu_manufacturer_name><trans_psu_model_name>DPS-160AB-18 C</trans_psu_model_name><trans_psu_model_number>DPS-160AB-18 C</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><date_available_on_market>2021-10-15T00:00:00</date_available_on_market><date_qualified>2021-10-30T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_AFF A250_20219130135356_5396765</energy_star_model_identifier></row><row _id="row-4yb2_i57p~e8zh" _uuid="00000000-0000-0000-A351-FE0415E9936D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2396769"><pd_id>2396769</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>FAS Series</model_name><model_number>FAS2720</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>FAS Series</storage_controller_model_name><storage_controller_model_number>FAS2720</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>No</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.9.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Multi-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta Electronics (Thailand) PCL</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900DB A</trans_psu_model_name><trans_psu_model_number>TDPS-900DB A</trans_psu_model_number><trans_psu_rated_output_w>900</trans_psu_rated_output_w><date_available_on_market>2022-05-22T00:00:00</date_available_on_market><date_qualified>2022-05-19T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_FAS2720_20224122171909_2972812</energy_star_model_identifier></row><row _id="row-je6p~vsgi~9e43" _uuid="00000000-0000-0000-2438-1DD28F747C34" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2667937"><pd_id>2667937</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A-Series</model_name><model_number>AFF-A150</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>NetApp - AFF A-Series</storage_controller_model_name><storage_controller_model_number>AFF-A150</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>ONTAP 9.13.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-900AB A</trans_psu_model_name><trans_psu_model_number>TDPS-900AB A</trans_psu_model_number><trans_psu_rated_output_w>913</trans_psu_rated_output_w><date_available_on_market>2023-03-30T00:00:00</date_available_on_market><date_qualified>2023-09-12T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_AFF-A150_20238115152112_2230149</energy_star_model_identifier></row><row _id="row-rwup_hrnx~sjmc" _uuid="00000000-0000-0000-D1BE-ECA53B16E18B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3893954"><pd_id>3893954</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A-Series</model_name><model_number>AFF-A90</model_number><snia_online_taxonomy_category>Disk Set Online 3</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp</storage_controller_manufacturer_name><storage_controller_model_name>AFF</storage_controller_model_name><storage_controller_model_number>A90</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.15.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>not capable</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>not capable</length_of_rolling_average_for_inlet_air_temperature_s><date_available_on_market>2024-07-01T00:00:00</date_available_on_market><date_qualified>2025-01-06T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_AFF-A90_20250113164754_1347455</energy_star_model_identifier></row><row _id="row-zsu8_cfw8_7uzu" _uuid="00000000-0000-0000-EC08-F85AA33B1593" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4429175"><pd_id>4429175</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A800</model_name><model_number>AFF A800</model_number><additional_model_information>AFF C800,AFF C800</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp, Inc</storage_controller_manufacturer_name><storage_controller_model_name>AFF A800</storage_controller_model_name><storage_controller_model_number>AFF A800</storage_controller_model_number><storage_controller_advanced_data_recovery_type>Snapshot</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>ONTAP 9.15.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>real-time</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>real-time</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>AFF A800</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>TDPS1600GB A</trans_psu_model_name><trans_psu_model_number>TDPS1600GB A</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>1374.389535</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>Other</trans_devices_used_for_cache><trans_other_devices_used_for_cache>RAM</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>48</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>484</trans_installed_solid_state_devices_in_optimal_point><trans_number_of_psus_optimal_point>4</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_random_read_workload_test_iops_w>401.69</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>55.11</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>425.36</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-01-01T00:00:00</date_available_on_market><date_qualified>2025-03-04T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1093185_AFF A800_052720252107931_8513451</energy_star_model_identifier></row><row _id="row-9xeu~64qu-gskv" _uuid="00000000-0000-0000-CD3C-C8610E90B2D5" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4517950"><pd_id>4517950</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A50</model_name><model_number>AFF A50</model_number><additional_model_information>ASA A50,ASA A50</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp Inc</storage_controller_manufacturer_name><storage_controller_model_name>AFF A50</storage_controller_model_name><storage_controller_model_number>AFF A50</storage_controller_model_number><storage_controller_advanced_data_recovery_type>All-Flash Arrays</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.16.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>NA</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>NA</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>X4024S173A1T9NTE</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Ac-Dc</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta,  QCS</trans_psu_manufacturer_name><trans_psu_model_number>TDPS-1600GB A, DCJ16002-06</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>127.9900254</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_storage_device_1_type>Solid State Drive (SSD)</trans_storage_device_1_type><trans_storage_device_1_raw_capacity_gb>1739.998626</trans_storage_device_1_raw_capacity_gb><trans_automated_tiering_enabled_during_testing_device_1>Yes</trans_automated_tiering_enabled_during_testing_device_1><trans_device_1_optimal_point_hot_band_wrkld_test_iops_w>352.50</trans_device_1_optimal_point_hot_band_wrkld_test_iops_w><trans_device_1_optimal_point_random_read_wrkld_test_iops_w>665.27</trans_device_1_optimal_point_random_read_wrkld_test_iops_w><trans_device_1_optimal_point_random_write_wrkld_test_iops_w>296.37</trans_device_1_optimal_point_random_write_wrkld_test_iops_w><trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w>51.50</trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2025-11-25T00:00:00</date_available_on_market><date_qualified>2025-12-10T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1093185_AFF A50_121020251345112_5677625</energy_star_model_identifier></row><row _id="row-8sp7.ka8n-fvac" _uuid="00000000-0000-0000-4B8A-686DA0CE6260" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4576655"><pd_id>4576655</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A30</model_name><model_number>AFF A30</model_number><additional_model_information>AFF C30; ASA A30; ASA C30</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp Inc.</storage_controller_manufacturer_name><storage_controller_model_name>AFF A50</storage_controller_model_name><storage_controller_model_number>AFF A50</storage_controller_model_number><storage_controller_advanced_data_recovery_type>All-Flash Arrays</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.18.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>0</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>0</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>X4024S173A1T9NTE</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta, QCS</trans_psu_manufacturer_name><trans_psu_model_number>TDPS-1600GB A, DCJ16002-06</trans_psu_model_number><trans_psus_80plus_certification>Titanium Certification</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>137.4389535</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>234.56</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>438.92</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>209.83</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>0.17</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2026-03-10T00:00:00</date_available_on_market><date_qualified>2026-03-11T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1093185_AFF A30_031120261823963_8023301</energy_star_model_identifier></row><row _id="row-inbt-zrfq_8d9p" _uuid="00000000-0000-0000-EACB-3569B8B20477" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4618414"><pd_id>4618414</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>AFF A20</model_name><model_number>AFF A20</model_number><additional_model_information>ASA A20,ASA A20,Marketing Purposes</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp Inc</storage_controller_manufacturer_name><storage_controller_model_name>AFF A50</storage_controller_model_name><storage_controller_model_number>AFF A50</storage_controller_model_number><storage_controller_advanced_data_recovery_type>All-Flash Arrays</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression,Data Deduplication,Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>ONTAP</software_operating_environment_name><software_operating_environment_version>9.18.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>1</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>1</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>X4024S173A1T9NTE</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Ac-Dc</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta, QCS</trans_psu_manufacturer_name><trans_psu_model_name>TDPS-1600GB A, DCJ16002-06</trans_psu_model_name><trans_psu_model_number>TDPS-1600GB A, DCJ16002-06</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>137.4389535</trans_total_amount_of_cache_gb><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>24</trans_installed_solid_state_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>591.66</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>628.11</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>595.44</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>0.17</trans_optimal_point_ready_idle_workload_test_gb_w><trans_automated_tiering_enabled_during_testing_device_1>Yes</trans_automated_tiering_enabled_during_testing_device_1><date_available_on_market>2025-01-01T00:00:00</date_available_on_market><date_qualified>2026-05-29T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1093185_AFF A20_052920261816450_4810936</energy_star_model_identifier></row><row _id="row-a6xk-gqrh_ach4" _uuid="00000000-0000-0000-DDF5-B102A9D2D1BC" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4680634"><pd_id>4680634</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp Inc</brand_name><model_name>EF50</model_name><model_number>EF50</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp Inc</storage_controller_manufacturer_name><storage_controller_model_name>EF50</storage_controller_model_name><storage_controller_model_number>EF50</storage_controller_model_number><storage_controller_advanced_data_recovery_type>All-Flash Arrays</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><software_operating_environment_name>SANTricity</software_operating_environment_name><software_operating_environment_version>12.00R1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>1</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>1</length_of_rolling_average_for_inlet_air_temperature_s><trans_optimal_point_hot_band_workload_test_iops_w>580.53</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>628.11</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>367.71</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>0.05</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2026-01-01T00:00:00</date_available_on_market><date_qualified>2026-07-30T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1093185_EF50_073020261620507_6068429</energy_star_model_identifier></row><row _id="row-e8w9-xrha.d6q7" _uuid="00000000-0000-0000-C2D5-DAE900D2038B" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4711794"><pd_id>4711794</pd_id><energy_star_partner>NetApp, Inc.</energy_star_partner><brand_name>NetApp</brand_name><model_name>EF80</model_name><model_number>EF80</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>NetApp Inc</storage_controller_manufacturer_name><storage_controller_model_name>EF80</storage_controller_model_name><storage_controller_model_number>EF80</storage_controller_model_number><storage_controller_advanced_data_recovery_type>All-Flash Arrays</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>SANTricity</software_operating_environment_name><software_operating_environment_version>12.00R1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>1</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>1</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>MZWLR1T9HCJR-0G5</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Internal</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>QCS &amp; LiteOn</trans_psu_manufacturer_name><trans_psu_model_name>DCJ20002-03 &amp; PS-2022-10E</trans_psu_model_name><trans_psu_model_number>DCJ20002-03 &amp; PS-2022-10E</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_other_devices_used_for_cache>64</trans_other_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>24</trans_total_num_installed_storage_devices_optimal_point><trans_installed_rotational_devices_in_optimal_point>MZWLR1T9HCJR-0G5</trans_installed_rotational_devices_in_optimal_point><trans_num_of_controllers_in_optimal_point>24</trans_num_of_controllers_in_optimal_point><trans_auto_tiering_enabled_optimal_point>Yes</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>480.79</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>5185.53</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>459.87</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>0.08</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2026-09-25T00:00:00</date_available_on_market><date_qualified>2026-09-30T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1093185_EF80_093020261808841_5725245</energy_star_model_identifier></row><row _id="row-mksa-rcb3.6c9g" _uuid="00000000-0000-0000-FA76-C412304DA670" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2732042"><pd_id>2732042</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//XL</model_name><model_number>FlashArray//XL</model_number><additional_model_information>FlashArray//XL130; FlashArray//XL170</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//XL170</storage_controller_model_name><storage_controller_model_number>FlashArray//XL170</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.4.9</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>0</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>0</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>FlashArray//XL170</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Artesyn</trans_psu_manufacturer_name><trans_psu_model_name>CSU2400AP-3-400</trans_psu_model_name><trans_psu_model_number>CSU2400AP-3-400</trans_psu_model_number><trans_psu_rated_output_w>2400</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>2000.005208</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>30 DFMDs</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>40.56</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>62.07</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>78.65</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>1210.88</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2021-12-08T00:00:00</date_available_on_market><date_qualified>2023-11-02T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1132228_FlashArray//XL_101920231700886_8647240</energy_star_model_identifier></row><row _id="row-smzd~5xzu_swzn" _uuid="00000000-0000-0000-CAC0-45A543309898" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2732043"><pd_id>2732043</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//XR4</model_name><model_number>FlashArray//XR4</model_number><additional_model_information>FlashArray//X20R4; FlashArray//X50R4; FlashArray//X70R4; FlashArray//X90R4</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//X90R4</storage_controller_model_name><storage_controller_model_number>FlashArray//X90R4</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.4.10</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>0</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>0</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>FlashArray//X90R4</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>DPS-1600AB-13 U</trans_psu_model_name><trans_psu_model_number>DPS-1600AB-13 U</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>2000.005208</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>20 DFMs</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>55.12</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>82.57</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>118.68</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>910.86</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2023-06-14T00:00:00</date_available_on_market><date_qualified>2023-11-02T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1132228_FlashArray//XR4_101920231603199_1881606</energy_star_model_identifier></row><row _id="row-ctu6~e4i6_6prb" _uuid="00000000-0000-0000-1728-7169528C6B9D" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/2814192"><pd_id>2814192</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//CR4</model_name><model_number>FlashArray//CR4</model_number><additional_model_information>FlashArray//C50R4; FlashArray//C70R4; FlashArray//C90R4</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//C90R4</storage_controller_model_name><storage_controller_model_number>FlashArray//C90R4</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.4.10</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>-</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>-</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>FlashArray//C90R4</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>DPS-1600AB-13 U</trans_psu_model_name><trans_psu_model_number>DPS-1600AB-13 U</trans_psu_model_number><trans_psu_rated_output_w>1600</trans_psu_rated_output_w><trans_psus_80plus_certification>Platinum</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>2000.005208</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>20 DFMcs</trans_total_num_installed_storage_devices_optimal_point><trans_num_of_controllers_in_optimal_point>1</trans_num_of_controllers_in_optimal_point><trans_num_redundant_controllers_optimal_point>0</trans_num_redundant_controllers_optimal_point><trans_number_of_psus_optimal_point>2</trans_number_of_psus_optimal_point><trans_number_of_redundant_psus_optimal_point>2</trans_number_of_redundant_psus_optimal_point><trans_auto_tiering_enabled_optimal_point>No</trans_auto_tiering_enabled_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>30.20</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>56.09</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>112.45</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>2100.87</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2023-06-14T00:00:00</date_available_on_market><date_qualified>2023-12-01T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1132228_FlashArray//CR4_112920232142193_5875438</energy_star_model_identifier></row><row _id="row-y745.7hj5~dhzf" _uuid="00000000-0000-0000-5F23-9BBC7D621FB3" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3417656"><pd_id>3417656</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//E</model_name><model_number>FlashArray//E</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//E</storage_controller_model_name><storage_controller_model_number>FlashArray//E</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.6.2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>0</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>0</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>FlashArray//E</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>Single-Output</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Artesyn</stream_psu_manufacturer_name><stream_psu_model_name>CSU1800AP-3-400</stream_psu_model_name><stream_psu_model_number>CSU1800AP-3-400</stream_psu_model_number><stream_psu_rated_output_w>1800</stream_psu_rated_output_w><stream_psus_80plus_certification>Platinum</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>2000.005208</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>14 wSSDs</stream_total_num_installed_storage_devices_optimal_point><stream_num_of_controllers_in_optimal_point>1</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>0</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>2</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>No</stream_auto_tiering_enabled_optimal_point><stream_optimal_point_seq_read_workload_test_mibps_w>2.31</stream_optimal_point_seq_read_workload_test_mibps_w><stream_optimal_point_seq_write_workload_test_mibps_w>0.99</stream_optimal_point_seq_write_workload_test_mibps_w><stream_optimal_point_ready_idle_workload_test_gb_w>877.08</stream_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2023-06-14T00:00:00</date_available_on_market><date_qualified>2024-02-29T00:00:00</date_qualified><markets>United States, Canada</markets><energy_star_model_identifier>ES_1132228_FlashArray//E_020620242201765_1267330</energy_star_model_identifier></row><row _id="row-8mqg_cjvq_mt6x" _uuid="00000000-0000-0000-7DE3-A980FB38E531" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4429196"><pd_id>4429196</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//RC20</model_name><model_number>FlashArray//RC20</model_number><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//RC20</storage_controller_model_name><storage_controller_model_number>FlashArray//RC20</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.8.3</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>0</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>0</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>DirectFlash Module (c) (DFMc)</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Single-Output</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>DPS-1600AB-52 B</trans_psu_model_name><trans_psu_model_number>DPS-1600AB-52 B</trans_psu_model_number><trans_psu_rated_output_w>1600W</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>618.4752906</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>8</trans_total_num_installed_storage_devices_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>128.56</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>581.29</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>637.23</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>481.11</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-04-09T00:00:00</date_available_on_market><date_qualified>2025-05-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1132228_FlashArray//RC20_052720251606287_7335416</energy_star_model_identifier></row><row _id="row-hbti-t995_hnba" _uuid="00000000-0000-0000-3666-0E82790D12E1" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4498454"><pd_id>4498454</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//XR5</model_name><model_number>FlashArray//XR5</model_number><additional_model_information>//X20R5; //X50R5; //X70R5; //X90R5</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//X90R5</storage_controller_model_name><storage_controller_model_number>FlashArray//X90R5</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.10.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>N/A</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>N/A</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>DirectFlash Module (DFM)</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Redundant Power Supply</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>Delta</trans_psu_model_name><trans_psu_model_number>DPS-2000AB-33 C</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_total_amount_of_cache_gb>2.147483648</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>28 DFMs</trans_total_num_installed_storage_devices_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>220.57</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>391.01</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>455.50</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>1.33</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-08-15T00:00:00</date_available_on_market><date_qualified>2025-09-09T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1132228_FlashArray//XR5_090820251740220_7930947</energy_star_model_identifier></row><row _id="row-h5cd~i7w8.277x" _uuid="00000000-0000-0000-A779-3071D0E905DE" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4498473"><pd_id>4498473</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//CR5</model_name><model_number>FlashArray//CR5</model_number><additional_model_information>//C50R5; //C70R5; //C90R5</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//CR5</storage_controller_model_name><storage_controller_model_number>FlashArray//CR5</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.10.1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>N/A</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>N/A</length_of_rolling_average_for_inlet_air_temperature_s><trans_power_supply_unit_psu_type>Redundant Power Supply</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta</trans_psu_manufacturer_name><trans_psu_model_name>Delta</trans_psu_model_name><trans_psu_model_number>DPS-2000AB-33 C</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>28 DFMcs</trans_total_num_installed_storage_devices_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>189.38</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>360.07</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>480.99</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>1.34</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-08-15T00:00:00</date_available_on_market><date_qualified>2025-09-09T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1132228_FlashArray//CR5_090920251856145_6724022</energy_star_model_identifier></row><row _id="row-48br-s2a2_9jk6" _uuid="00000000-0000-0000-1017-0DC397904A8F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/4499114"><pd_id>4499114</pd_id><energy_star_partner>Pure Storage, Inc.</energy_star_partner><brand_name>Pure Storage</brand_name><model_name>FlashArray//XLR5</model_name><model_number>FlashArray//XLR5</model_number><additional_model_information>FlashArray//XL130R5; FlashArray//XL170R5; FlashArray//XL190R5</additional_model_information><snia_online_taxonomy_category>NVSS Disk Set Online 4</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Pure Storage, Inc.</storage_controller_manufacturer_name><storage_controller_model_name>FlashArray//XL170R5</storage_controller_model_name><storage_controller_model_number>FlashArray//XL170R5</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Delta Snapshots,Thin Provisioning,Compression,Data Deduplication</capacity_optimizing_methods_coms><workload_optimization_type>Transaction</workload_optimization_type><automated_storage_tiering_capable>No</automated_storage_tiering_capable><software_operating_environment_name>Purity</software_operating_environment_name><software_operating_environment_version>6.8.10</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Both</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>n/a</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>n/a</length_of_rolling_average_for_inlet_air_temperature_s><trans_model_number_or_config_id>DirectFlash Module (c) (DFMc)</trans_model_number_or_config_id><trans_power_supply_unit_psu_type>Ac-Dc: Single-Output: Redundant Power Supply</trans_power_supply_unit_psu_type><trans_psu_manufacturer_name>Delta, Artesyn</trans_psu_manufacturer_name><trans_psu_model_name>Delta, Artesyn</trans_psu_model_name><trans_psu_model_number>DPS-2000AB-33 C , CSU2000AT-3-400</trans_psu_model_number><trans_psu_rated_output_w>2000</trans_psu_rated_output_w><trans_psus_80plus_certification>Titanium</trans_psus_80plus_certification><trans_total_amount_of_cache_gb>187.4967973</trans_total_amount_of_cache_gb><trans_devices_used_for_cache>DRAM</trans_devices_used_for_cache><trans_total_num_installed_storage_devices_optimal_point>20</trans_total_num_installed_storage_devices_optimal_point><trans_installed_solid_state_devices_in_optimal_point>40</trans_installed_solid_state_devices_in_optimal_point><trans_optimal_point_hot_band_workload_test_iops_w>330.66</trans_optimal_point_hot_band_workload_test_iops_w><trans_optimal_point_random_read_workload_test_iops_w>341.13</trans_optimal_point_random_read_workload_test_iops_w><trans_optimal_point_random_write_workload_test_iops_w>275.36</trans_optimal_point_random_write_workload_test_iops_w><trans_optimal_point_ready_idle_workload_test_gb_w>0.63</trans_optimal_point_ready_idle_workload_test_gb_w><date_available_on_market>2025-06-07T00:00:00</date_available_on_market><date_qualified>2025-09-17T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1132228_FlashArray//XLR5_091720251706235_1887962</energy_star_model_identifier></row><row _id="row-wfdk-kns6.2v76" _uuid="00000000-0000-0000-F305-496449C31916" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550164"><pd_id>3550164</pd_id><energy_star_partner>Seagate Technologies LLC</energy_star_partner><brand_name>Seagate</brand_name><model_name>HB-1235</model_name><model_number>HB-1235</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>IND xX controller  (Where "x" can e  A, E,L,N)</storage_controller_model_name><storage_controller_model_number>IND LX</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>20700</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>20700</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>HB-1235</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>26.39257403</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>24</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>24</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>3.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>7200.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>8.589934592</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>4</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>4.77</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>6.40</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>369.00</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2020-09-08T00:00:00</date_available_on_market><date_qualified>2024-06-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1130247_HB-1235_06282024154823_2157106</energy_star_model_identifier></row><row _id="row-8hcz_ed35~j8na" _uuid="00000000-0000-0000-9FF4-1151A1F72E8F" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3550165"><pd_id>3550165</pd_id><energy_star_partner>Seagate Technologies LLC</energy_star_partner><brand_name>Seagate</brand_name><model_name>EB-2425</model_name><model_number>EB-2425</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>IND xX controller  (Where "x" can e  A, E,L,N)</storage_controller_model_name><storage_controller_model_number>IND LX</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Compression</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>1</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>20700</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>20700</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>EB-2425</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SP-PCM02-HE580-AC</stream_psu_model_number><stream_psu_rated_output_w>584</stream_psu_rated_output_w><stream_psus_80plus_certification>Gold</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>26.39257403</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>48</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>48</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>Yes</stream_auto_tiering_enabled_optimal_point><stream_storage_device_2_type>Hard Disk Drive (HDD)</stream_storage_device_2_type><stream_storage_device_2_form_factor>2.5 inch</stream_storage_device_2_form_factor><stream_storage_device_2_rated_speed_rpm>1500.00</stream_storage_device_2_rated_speed_rpm><stream_storage_device_2_raw_capacity_gb>1.932735283</stream_storage_device_2_raw_capacity_gb><stream_num_devices_storage_device_2_optimal_point>4</stream_num_devices_storage_device_2_optimal_point><stream_physical_or_modeled_data_device_2_optimal_point>Physical</stream_physical_or_modeled_data_device_2_optimal_point><stream_automated_tiering_enabled_during_testing_device_2>Yes</stream_automated_tiering_enabled_during_testing_device_2><stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w>5.21</stream_device_2_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w>7.63</stream_device_2_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w>104.16</stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2020-09-08T00:00:00</date_available_on_market><date_qualified>2024-06-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1130247_EB-2425_06282024162134_5816906</energy_star_model_identifier></row><row _id="row-cnre~qt6r.2v5g" _uuid="00000000-0000-0000-670A-BF87D5B21B34" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3554642"><pd_id>3554642</pd_id><energy_star_partner>Seagate Technologies LLC</energy_star_partner><brand_name>Seagate</brand_name><model_name>SP-2584</model_name><model_number>SP-2584</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Out Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>Indium LXxx</storage_controller_model_name><storage_controller_model_number>Indium LX2</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>IN100</software_operating_environment_name><software_operating_environment_version>2</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>SP-2584</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Switching Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Flextronics</stream_psu_manufacturer_name><stream_psu_model_name>UD-PCM2-2200-AC</stream_psu_model_name><stream_psu_model_number>SGT-S-2200ADE00</stream_psu_model_number><stream_psu_rated_output_w>2200</stream_psu_rated_output_w><stream_psus_80plus_certification>Titanium</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>DRAM</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>84</stream_total_num_installed_storage_devices_optimal_point><stream_ratio_devices_mixed_optimal_point>0</stream_ratio_devices_mixed_optimal_point><stream_installed_solid_state_devices_in_optimal_point>0</stream_installed_solid_state_devices_in_optimal_point><stream_installed_rotational_devices_in_optimal_point>84</stream_installed_rotational_devices_in_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>Yes</stream_auto_tiering_enabled_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>3.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>7200.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>19531.36378</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>84</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>4.14</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>5.65</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>1075.07</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2022-10-28T00:00:00</date_available_on_market><date_qualified>2024-06-28T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1130247_SP-2584_07172024130245_2179076</energy_star_model_identifier></row><row _id="row-jt76_wbew-4p9h" _uuid="00000000-0000-0000-64C8-869AE1D37610" _position="0" _address="https://data.energystar.gov/resource/_3uec-2gqf/3814873"><pd_id>3814873</pd_id><energy_star_partner>Seagate Technologies LLC</energy_star_partner><brand_name>Seagate</brand_name><model_name>Exos CORVAULT SCS-P4106</model_name><model_number>Exos CORVAULT SCS-P4106</model_number><snia_online_taxonomy_category>Disk Set Online 2</snia_online_taxonomy_category><storage_controller_implementation>Scale-Up Storage</storage_controller_implementation><storage_controller_manufacturer_name>Seagate Technology LLC</storage_controller_manufacturer_name><storage_controller_model_name>Indium</storage_controller_model_name><storage_controller_model_number>Indium EC2</storage_controller_model_number><storage_controller_advanced_data_recovery_type>RAID</storage_controller_advanced_data_recovery_type><capacity_optimizing_methods_coms>Thin Provisioning</capacity_optimizing_methods_coms><workload_optimization_type>Streaming</workload_optimization_type><automated_storage_tiering_capable>Yes</automated_storage_tiering_capable><automated_storage_tiering_enabled_in_hardware_on_shipment>Yes</automated_storage_tiering_enabled_in_hardware_on_shipment><software_operating_environment_name>S120</software_operating_environment_name><software_operating_environment_version>S120</software_operating_environment_version><active_or_passive_cooling_enabled_in_hardware_on_shipment>Active Cooling</active_or_passive_cooling_enabled_in_hardware_on_shipment><length_of_rolling_average_for_input_power_s>10</length_of_rolling_average_for_input_power_s><length_of_rolling_average_for_inlet_air_temperature_s>10</length_of_rolling_average_for_inlet_air_temperature_s><stream_model_number_or_config_id>SCS-P4106</stream_model_number_or_config_id><stream_power_supply_unit_psu_type>AC-DC Power Supply</stream_power_supply_unit_psu_type><stream_psu_manufacturer_name>Bel Power</stream_psu_manufacturer_name><stream_psu_model_name>Switching Power Supply</stream_psu_model_name><stream_psu_model_number>SPASGAT-02</stream_psu_model_number><stream_psu_rated_output_w>2000</stream_psu_rated_output_w><stream_psus_80plus_certification>Titanium</stream_psus_80plus_certification><stream_total_amount_of_cache_gb>0</stream_total_amount_of_cache_gb><stream_devices_used_for_cache>Other</stream_devices_used_for_cache><stream_total_num_installed_storage_devices_optimal_point>106</stream_total_num_installed_storage_devices_optimal_point><stream_num_of_controllers_in_optimal_point>2</stream_num_of_controllers_in_optimal_point><stream_num_redundant_controllers_optimal_point>1</stream_num_redundant_controllers_optimal_point><stream_number_of_psus_optimal_point>2</stream_number_of_psus_optimal_point><stream_number_of_redundant_psus_optimal_point>1</stream_number_of_redundant_psus_optimal_point><stream_auto_tiering_enabled_optimal_point>Yes</stream_auto_tiering_enabled_optimal_point><stream_storage_device_1_type>Hard Disk Drive (HDD)</stream_storage_device_1_type><stream_storage_device_1_form_factor>3.5 inch</stream_storage_device_1_form_factor><stream_storage_device_1_rated_speed_rpm>7200.00</stream_storage_device_1_rated_speed_rpm><stream_storage_device_1_raw_capacity_gb>20000.05208</stream_storage_device_1_raw_capacity_gb><stream_num_devices_storage_device_1_optimal_point>106</stream_num_devices_storage_device_1_optimal_point><stream_physical_or_modeled_data_device_1_optimal_point>Physical</stream_physical_or_modeled_data_device_1_optimal_point><stream_automated_tiering_enabled_during_testing_device_1>Yes</stream_automated_tiering_enabled_during_testing_device_1><stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w>4.03</stream_device_1_optimal_point_seq_read_wrkld_test_mibps_w><stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w>2.12</stream_device_1_optimal_point_seq_write_wrkld_test_mibps_w><stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w>1358.56</stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w><date_available_on_market>2022-01-01T00:00:00</date_available_on_market><date_qualified>2024-11-21T00:00:00</date_qualified><markets>United States</markets><energy_star_model_identifier>ES_1130247_CORVAULTSCSP4106_11222024155905_9994814</energy_star_model_identifier></row></row></response>